BI98 is the 98-cabinet member of the legacy built-in ice maker family. A problem pattern specific to old crescent machines is worth describing, because owners often misread it: when the mold overfills because the water valve is seeping, the ice freezes into a single slab rather than separate crescents, and the harvest cannot release it. The sign looks like a jammed harvest, but the cause is upstream at the valve.
Key Features
- Built-in crescent ice maker, 98 cabinet code
- Harvest-cycle ice production
- Mechanical controls with no problem display
- Undercounter built-in installation
Most Common Issues on This Model
Scale on the evaporator plate preventing clean harvest
Water valve seeping and overfilling the mold
Compressor start parts fatigued