An undercounter freezer works a great deal harder than a refrigerator in the same cabinet, and a 1224FZR that has been holding zero degrees for fifteen years has put considerably more hours on its compressor than a 1224R of the same age. That said, the problem that actually brings these in is almost always the defrost circuit, and the compressor generally has plenty of life left when the defrost heater does not.
Key Features
- 24" undercounter freezer
- Frozen storage in an Origin-series cabinet
- Solid door
- Built-in or freestanding installation
Most Common Issues on This Model
Frost build-up from a failed defrost part
Door seal freezing to the frame
Freezer holding temperature but never cycling off